Start from what the pump has to do. Each application lists the CNP series that suit it, taken from the catalogue.
Building water supply and pressure boosting
Domestic and commercial water supply, boosting and pressurising from tanks or mains.
Vertical multistage (CDM, CDL) and horizontal multistage (CM, CHL, CHM) pumps suit high head at moderate flow; TD and ZS suit larger flows at lower head.
What we need to select a pump
Required flow and total head, including pipe friction and static lift
Number of outlets / peak demand
Inlet condition: mains, tank (suction lift or flooded)
Electric supply (single / three phase)
Watch out for
A single flow-and-head match is not enough: check NPSH on suction lift and start-stop frequency
Choose a pump whose duty sits near the middle of its curve, not at the far end
Add a pressure tank or variable-speed control if demand varies widely
Series to consider (a flow-and-head match alone does not make a pump suitable)
Water from wells and tanks, irrigation and lowering ground water.
SJ is the deep-well submersible; PQ is a shorter submersible for tanks, fountains and boosting. Axial and mixed-flow pumps cover large irrigation flows.
What we need to select a pump
Static and pumping water level, well diameter
Required flow at delivery head
Sand / solids content
Supply and cable length
Watch out for
The pump must fit the bore and be set below the pumping level
Sand shortens life: say if the water carries sand
Confirm motor cooling and cable voltage drop for long lowering depths
Series to consider (a flow-and-head match alone does not make a pump suitable)
Storm and flood drainage, site dewatering, reservoir transfer.
QZB axial-flow and QHB mixed-flow pumps give the largest flows at low head; QF and WQ suit smaller drainage; SP is self-priming for construction sites.
What we need to select a pump
Flow and lift
Water type (clean, muddy, with sand)
Portable or fixed installation
Power supply on site
Watch out for
Gritty water needs a drainage-type pump, not a clean-water pump
Check the discharge hose / pipe size and friction in the head
Confirm float or level control
Series to consider (a flow-and-head match alone does not make a pump suitable)
This part of the website is limited to authorised CNP Pakistan staff at the moment. We are preparing it for everyone. If you need technical data, a datasheet or a quotation in the meantime, please contact our sales team and we will gladly help.