SP (self-priming sewage)
Non-clogging self-priming sewage pump
- Flow 10–750 m³/h
- Head up to 38 m
- 0.75–90 kW
Submersible sewage pump, WQ-W(I) non-clogging cutting (50 Hz)
WQ-W(I): submersible sewage pump from the CNP range. 32 models, flow 9 to 300 m³/h, head up to 32 m, motors 0.37 to 15 kW. Typical duties: sewage treatment systems for buildings, hospitals, residential areas, municipal and industrial projects; drainage and waste-water treatment; mines and prospecting. Open a model for its rated duty, dimensions and datasheet, or send us your duty and we will confirm the selection.

CNP-S-000110The 32 models of the WQ-W(I) range grouped by outlet size. Open the Models tab for every model with its performance data.
| Outlet size | Head | Power | Outlet | Models | |
|---|---|---|---|---|---|
| DN40 outlet | 5–15 m | 0.37–1.5 kW | DN40 | 4 | |
| DN50 outlet | 7–32 m | 0.55–5.5 kW | DN50 | 8 | |
| DN65 outlet | 10–28 m | 1.1–7.5 kW | DN65 | 7 | |
| DN80 outlet | 8–22 m | 2.2–5.5 kW | DN80 | 4 | |
| DN100 outlet | 10–17 m | 3–7.5 kW | DN100 | 4 | |
| DN150 outlet | 10–16 m | 7.5–15 kW | DN150 | 3 | |
| DN200 outlet | 10 m | 11–15 kW | DN200 | 2 |
Filter by duty point, mains frequency or size. Click a model for its performance curve and data.
| Model | Series | Power kW | rpm | Outlet | kg | |||
|---|---|---|---|---|---|---|---|---|
| 40WQ9-5-0.37W(I) | WQ-W(I) | 0.37 | 2800 | DN40 | 16 | |||
| 40WQ10-7-0.55W(I) | WQ-W(I) | 0.55 | 2850 | DN40 | 20 | |||
| 40WQ10-10-0.75W(I) | WQ-W(I) | 0.75 | 2850 | DN40 | 23 | |||
| 40WQ12-15-1.5W(I) | WQ-W(I) | 1.5 | 2880 | DN40 | 35 | |||
| 50WQ10-13-1.1W(I) | WQ-W(I) | 1.1 | 2850 | DN50 | 27 | |||
| 50WQ10-7-0.55W(I) | WQ-W(I) | 0.55 | 2850 | DN50 | 20 | |||
| 50WQ10-10-0.75W(I) | WQ-W(I) | 0.75 | 2850 | DN50 | 23 | |||
| 50WQ12-15-1.5W(I) | WQ-W(I) | 1.5 | 2880 | DN50 | 35 | |||
| 50WQ15-18-2.2W(I) | WQ-W(I) | 2.2 | 2880 | DN50 | 39 | |||
| 50WQ15-25-3W(I) | WQ-W(I) | 3 | 2840 | DN50 | 47 | |||
| 50WQ25-25-4W(I) | WQ-W(I) | 4 | 2840 | DN50 | 52 | |||
| 50WQ18-32-5.5W(I) | WQ-W(I) | 5.5 | 2940 | DN50 | 86 | |||
| 65WQ15-10-1.1W(I) | WQ-W(I) | 1.1 | 2850 | DN65 | 29 | |||
| 65WQ25-10-1.5W(I) | WQ-W(I) | 1.5 | 2880 | DN65 | 38 | |||
| 65WQ25-14-2.2W(I) | WQ-W(I) | 2.2 | 2880 | DN65 | 42 | |||
| 65WQ25-18-3W(I) | WQ-W(I) | 3 | 2840 | DN65 | 48 | |||
| 65WQ40-16-4W(I) | WQ-W(I) | 4 | 2840 | DN65 | 52 | |||
| 65WQ30-25-5.5W(I) | WQ-W(I) | 5.5 | 2940 | DN65 | 87 | |||
| 80WQ40-8-2.2W(I) | WQ-W(I) | 2.2 | 2880 | DN80 | 49 | |||
| 80WQ35-13-3W(I) | WQ-W(I) | 3 | 2840 | DN80 | 51 | |||
| 80WQ50-12-4W(I) | WQ-W(I) | 4 | 2840 | DN80 | 55 | |||
| 80WQ40-22-5.5W(I) | WQ-W(I) | 5.5 | 2940 | DN80 | 87 | |||
| 100WQ50-10-3W(I) | WQ-W(I) | 3 | 2840 | DN100 | 50 | |||
| 100WQ60-11-4W(I) | WQ-W(I) | 4 | 2840 | DN100 | 55 | |||
| 100WQ65-15-5.5W(I) | WQ-W(I) | 5.5 | 2940 | DN100 | 92 | |||
| 65WQ45-28-7.5W(I) | WQ-W(I) | 7.5 | 2940 | DN65 | 100 | |||
| 100WQ70-17-7.5W(I) | WQ-W(I) | 7.5 | 2940 | DN100 | 100 | |||
| 150WQ140-10-7.5W(I) | WQ-W(I) | 7.5 | 2940 | DN150 | 120 | |||
| 150WQ140-14-11W-4(I) | WQ-W(I) | 11 | 1440 | DN150 | 216 | |||
| 200WQ210-10-11W-4(I) | WQ-W(I) | 11 | 1440 | DN200 | 255 | |||
| 150WQ200-16-15W-4(I) | WQ-W(I) | 15 | 1440 | DN150 | 237 | |||
| 200WQ300-10-15W-4(I) | WQ-W(I) | 15 | 1440 | DN200 | 260 |
Every model of the WQ-W(I) range on one chart: each dot is the rated duty point of one model. Click a line or dot to open that model with its full data.
Logarithmic scales. Published catalogue data for clean water; the correct model for your duty is confirmed by our engineers.
Net weight and the main dimensions of each model, in millimetres, from the catalogue. Open a model for the labelled dimension drawing.
| Model | Weight (kg) | Dim H | Dim H1 | Dim H2 | Dim F | Dim H3 |
|---|---|---|---|---|---|---|
| 40WQ9-5-0.37W(I) | 16 | 374 | 260 | 169 | 184 | 79 |
| 40WQ10-7-0.55W(I) | 20 | 420 | 285 | 189 | 222 | 99 |
| 40WQ10-10-0.75W(I) | 23 | 420 | 285 | 189 | 222 | 99 |
| 40WQ12-15-1.5W(I) | 35 | 478 | 340 | 202 | 269 | 112 |
| 50WQ10-13-1.1W(I) | 27 | 443 | 330 | 217 | 241 | 108 |
| 50WQ10-7-0.55W(I) | 20 | 420 | 285 | 209 | 222 | 99 |
| 50WQ10-10-0.75W(I) | 23 | 420 | 285 | 209 | 222 | 99 |
| 50WQ12-15-1.5W(I) | 35 | 478 | 340 | 222 | 269 | 114 |
| 50WQ15-18-2.2W(I) | 39 | 517 | 370 | 224 | 283 | 114 |
| 50WQ15-25-3W(I) | 47 | 547 | 400 | 225 | 283 | 115 |
| 50WQ25-25-4W(I) | 52 | 593 | 450 | 257 | 298 | 147 |
| 50WQ18-32-5.5W(I) | 86 | 814 | 540 | 244 | 324 | 134 |
| 65WQ15-10-1.1W(I) | 29 | 443 | 330 | 227 | 241 | 108 |
| 65WQ25-10-1.5W(I) | 38 | 485 | 350 | 230 | 279 | 110 |
| 65WQ25-14-2.2W(I) | 42 | 531 | 390 | 241 | 298 | 121 |
| 65WQ25-18-3W(I) | 48 | 550 | 390 | 236 | 278 | 116 |
| 65WQ40-16-4W(I) | 52 | 598 | 470 | 270 | 298 | 150 |
| 65WQ30-25-5.5W(I) | 87 | 824 | 590 | 270 | 324 | 150 |
| 80WQ40-8-2.2W(I) | 49 | 548 | 400 | 259 | 296 | 124 |
| 80WQ35-13-3W(I) | 51 | 575 | 430 | 265 | 283 | 131 |
| 80WQ50-12-4W(I) | 55 | 598 | 450 | 285 | 303 | 150 |
| 80WQ40-22-5.5W(I) | 87 | 825 | 590 | 285 | 324 | 150 |
| 100WQ50-10-3W(I) | 50 | 575 | 430 | 281 | 311 | 131 |
| 100WQ60-11-4W(I) | 55 | 630 | 500 | 315 | 303 | 165 |
| 100WQ65-15-5.5W(I) | 92 | 857 | 560 | 315 | 334 | 165 |
| 65WQ45-28-7.5W(I) | 100 | 855 | 590 | 316 | 351 | 150 |
| 100WQ70-17-7.5W(I) | 100 | 855 | 590 | 316 | 351 | 166 |
| 150WQ140-10-7.5W(I) | 120 | 890 | 620 | 383 | 390 | 173 |
| 150WQ140-14-11W-4(I) | 216 | 1097 | 750 | 535 | 575 | 325 |
| 200WQ210-10-11W-4(I) | 255 | 1113 | 760 | 530 | 568 | 320 |
| 150WQ200-16-15W-4(I) | 237 | 1167 | 800 | 535 | 572 | 325 |
| 200WQ300-10-15W-4(I) | 260 | 1184 | 810 | 535 | 546 | 320 |
Typical wear and service parts for this type of pump. The exact part, material and part number depend on the model, so send us the model code (or a nameplate photo) and we confirm and quote the right one.
| Part | What it does | |
|---|---|---|
| Mechanical seals (motor side and pump side) | Keep water out of the motor; the key service part | |
| Impeller | Passes the liquid and solids; wears with sand and grit | |
| O-rings and gaskets | Seal the motor housing and covers | |
| Bearings | Carry the rotor; replace with the seals at overhaul | |
| Seal-chamber oil | Lubricates and cools the seals; change at overhaul | |
| Power cable and cable gland | Supplies the motor; the gland must stay watertight |
Generic list for this pump type; it is not a part-number catalogue for the series. Our team confirms the correct part for your model before quoting.
| Pump power | Oil capacity | Remark |
|---|---|---|
| 2P-0.37kW | 320 | |
| 2P-0.55/0.75/1.1kW | 500 | 40/50WQ15-8-1.1(I); 40/50WQ15-13-1.1(I); 50WQ10-15-1.1QG(I); 50WQ15-12-1.1QG(I); 40/50WQ15-13-1.1JY(I); 40/50WQ15-8-1.1JY(I) |
| 2P-1.1kW | 670 | |
| 2P-1.5kW | 940 | |
| 2P-2.2kW | 1160 | |
| 2P-3kW | 1100 | |
| 2P-4kW | 1300 | |
| 2P-5.5kW | 2140 | |
| 2P-7.5/11/15kW | 2000 | |
| 6P-22/30/37kW | 9100 | |
| 6P-45/55/75kW | 14000 | |
| 8P-22kW | 9100 | |
| 4P-2.2kW | 1300 | |
| 4P-4kW | 1200 | |
| 4P-5.5kW | 4200 | |
| 4P-7.5kW | 4500 | |
| 4P-11kW | 5200 | |
| 4P-15kW | 5100 | |
| 4P-18.5/22kW | 4600 | |
| 4P-30kW | 8600 | |
| 4P-37/45kW | 9100 | |
| 4P-55/75kW | 9600 | |
| 4/6P-90-150kW | 25000 |
Oil capacity unit is not printed in the catalogue.
Performance values are taken from the published CNP catalogue data. Our engineers confirm the final selection for your liquid, temperature, supply and site before quoting.
Non-clogging self-priming sewage pump
Send us the flow and head you need, or the model code and nameplate details of the pump you are repairing. Our team replies with a quotation.
This part of the website is limited to authorised CNP Pakistan staff at the moment. We are preparing it for everyone. If you need technical data, a datasheet or a quotation in the meantime, please contact our sales team and we will gladly help.