CDM(F) rated
Vertical multistage pump (rated points), CDM(F) vertical multistage pump (models with rated point only)
CDM(F) rated: vertical multistage pump (rated points) from the CNP range. 107 models, flow 1 to 255 m³/h, head up to 317.5 m, motors 0.75 to 200 kW. Typical duties: boosting, pressurising, hvac and water treatment. Open a model for its rated duty, dimensions and datasheet, or send us your duty and we will confirm the selection.

CNP-S-000182- Flow
- Staff only
- Head
- Staff only
- Power
- 0.75–200 kW
- Mains
- 50 Hz
- Models
- 107
- Liquid temp.
- -15 to +70 C
Sizes
The 107 models of the CDM(F) rated range grouped by type. Open the Models tab for every model with its performance data.
| Type | Head | Power | Outlet | Models | |
|---|---|---|---|---|---|
| CDM1 | 78–220 m | 0.75–2.2 kW | — | 12 | |
| CDM3 | 102–181 m | 2.2–3 kW | — | 3 | |
| CDM5 | 118–200 m | 3–5.5 kW | — | 4 | |
| CDM20 | 107–193 m | 11–18.5 kW | — | 5 | |
| CDM95 | 15.5–167 m | 5.5–55 kW | — | 11 | |
| CDM125 | 24.5–254.5 m | 11–110 kW | — | 15 | |
| CDM155 | 18.5–202 m | 11–110 kW | — | 12 | |
| CDM185 | 27.5–317.5 m | 18.5–200 kW | — | 18 | |
| CDM215 | 28–273 m | 22–200 kW | — | 16 | |
| CDM255 | 31–227 m | 30–200 kW | — | 11 |
Models
Filter by duty point, mains frequency or size. Click a model for its performance curve and data.
| Model | Series | Power kW | rpm | Outlet | kg | |||
|---|---|---|---|---|---|---|---|---|
| CDM1-14 | CDM1 | 0.75 | 2900 | — | 28 | |||
| CDM1-16 | CDM1 | 1.1 | 2900 | — | 31 | |||
| CDM1-18 | CDM1 | 1.1 | 2900 | — | 32 | |||
| CDM1-20 | CDM1 | 1.1 | 2900 | — | 33 | |||
| CDM1-24 | CDM1 | 1.5 | 2900 | — | 39 | |||
| CDM1-26 | CDM1 | 1.5 | 2900 | — | 40 | |||
| CDM1-28 | CDM1 | 1.5 | 2900 | — | 41 | |||
| CDM1-29 | CDM1 | 1.5 | 2900 | — | 42 | |||
| CDM1-31 | CDM1 | 2.2 | 2900 | — | 44 | |||
| CDM1-35 | CDM1 | 2.2 | 2900 | — | 46 | |||
| CDM1-37 | CDM1 | 2.2 | 2900 | — | 47 | |||
| CDM1-39 | CDM1 | 2.2 | 2900 | — | 48 | |||
| CDM3-17 | CDM3 | 2.2 | 2900 | — | 38 | |||
| CDM3-26 | CDM3 | 3 | 2900 | — | 53 | |||
| CDM3-30 | CDM3 | 3 | 2900 | — | 55 | |||
| CDM5-19 | CDM5 | 3 | 2900 | — | 51 | |||
| CDM5-26 | CDM5 | 4 | 2900 | — | 61 | |||
| CDM5-31 | CDM5 | 5.5 | 2900 | — | 83 | |||
| CDM5-32 | CDM5 | 5.5 | 2900 | — | 84 | |||
| CDM20-9 | CDM20 | 11 | 2900 | — | 161 | |||
| CDM20-11 | CDM20 | 15 | 2900 | — | 180 | |||
| CDM20-13 | CDM20 | 15 | 2900 | — | 182 | |||
| CDM20-15 | CDM20 | 18.5 | 2900 | — | 202 | |||
| CDM20-16 | CDM20 | 18.5 | 2900 | — | 203 | |||
| CDM95-1-1 | CDM95 | 5.5 | 2950 | — | 134 | |||
| CDM95-1 | CDM95 | 7.5 | 2950 | — | 142 | |||
| CDM95-2-2 | CDM95 | 11 | 2950 | — | 218 | |||
| CDM95-2 | CDM95 | 15 | 2950 | — | 233 | |||
| CDM95-3-2 | CDM95 | 18.5 | 2950 | — | 246 | |||
| CDM95-3 | CDM95 | 22 | 2950 | — | 300 | |||
| CDM95-4 | CDM95 | 30 | 2950 | — | 367 | |||
| CDM95-5 | CDM95 | 37 | 2950 | — | 392 | |||
| CDM95-6 | CDM95 | 45 | 2950 | — | 497 | |||
| CDM95-7 | CDM95 | 55 | 2950 | — | 567 | |||
| CDM95-8-2 | CDM95 | 55 | 2950 | — | 572 | |||
| CDM125-1 | CDM125 | 11 | 2950 | — | 264 | |||
| CDM125-2-2 | CDM125 | 15 | 2950 | — | 291 | |||
| CDM125-2-1 | CDM125 | 18.5 | 2950 | — | 299 | |||
| CDM125-2 | CDM125 | 22 | 2950 | — | 352 | |||
| CDM125-3-1 | CDM125 | 30 | 2950 | — | 423 | |||
| CDM125-3 | CDM125 | 37 | 2950 | — | 443 | |||
| CDM125-4-2 | CDM125 | 37 | 2950 | — | 453 | |||
| CDM125-4 | CDM125 | 45 | 2950 | — | 551 | |||
| CDM125-5 | CDM125 | 55 | 2950 | — | 622 | |||
| CDM125-6 | CDM125 | 75 | 2950 | — | 777 | |||
| CDM125-7 | CDM125 | 75 | 2950 | — | 788 | |||
| CDM125-8 | CDM125 | 90 | 2950 | — | 819 | |||
| CDM125-9-2 | CDM125 | 90 | 2950 | — | 832 | |||
| CDM125-9 | CDM125 | 110 | 2950 | — | 1258 | |||
| CDM125-10 | CDM125 | 110 | 2950 | — | 1268 | |||
| CDM155-1-1 | CDM155 | 11 | 2950 | — | 265 | |||
| CDM155-1 | CDM155 | 15 | 2950 | — | 280 | |||
| CDM155-2-2 | CDM155 | 22 | 2950 | — | 352 | |||
| CDM155-2 | CDM155 | 30 | 2950 | — | 412 | |||
| CDM155-3-2 | CDM155 | 37 | 2950 | — | 443 | |||
| CDM155-3 | CDM155 | 45 | 2950 | — | 541 | |||
| CDM155-4-1 | CDM155 | 55 | 2950 | — | 611 | |||
| CDM155-5-2 | CDM155 | 75 | 2950 | — | 766 | |||
| CDM155-5 | CDM155 | 75 | 2950 | — | 767 | |||
| CDM155-6 | CDM155 | 90 | 2950 | — | 798 | |||
| CDM155-7 | CDM155 | 110 | 2950 | — | 1235 | |||
| CDM155-8-2 | CDM155 | 110 | 2950 | — | 1246 | |||
| CDM185-1-B | CDM185 | 18.5 | 2950 | — | 384 | |||
| CDM185-1-A | CDM185 | 22 | 2950 | — | 438 | |||
| CDM185-2-2B | CDM185 | 37 | 2980 | — | 535 | |||
| CDM185-2-2A | CDM185 | 45 | 2980 | — | 635 | |||
| CDM185-3-3B | CDM185 | 55 | 2980 | — | 707 | |||
| CDM185-3 | CDM185 | 75 | 2980 | — | 865 | |||
| CDM185-4-A-3B | CDM185 | 75 | 2980 | — | 886 | |||
| CDM185-4-3A-B | CDM185 | 90 | 2980 | — | 907 | |||
| CDM185-4-4A | CDM185 | 90 | 2980 | — | 907 | |||
| CDM185-5-2A-3B | CDM185 | 110 | 2980 | — | 1382 | |||
| CDM185-5-5A | CDM185 | 110 | 2980 | — | 1382 | |||
| CDM185-6-3A-3B | CDM185 | 132 | 2980 | — | 1468 | |||
| CDM185-6-6A | CDM185 | 132 | 2980 | — | 1469 | |||
| CDM185-7-4A-3B | CDM185 | 160 | 2980 | — | 1607 | |||
| CDM185-7-7A | CDM185 | 160 | 2980 | — | 1607 | |||
| CDM185-8-6A-2B | CDM185 | 200 | 2980 | — | 1565 | |||
| CDM185-8-6A | CDM185 | 200 | 2980 | — | 1574 | |||
| CDM185-8 | CDM185 | 200 | 2980 | — | 1574 | |||
| CDM215-1-B | CDM215 | 22 | 2950 | — | 437 | |||
| CDM215-1 | CDM215 | 37 | 2980 | — | 517 | |||
| CDM215-2-2B | CDM215 | 45 | 2980 | — | 635 | |||
| CDM215-2-A-B | CDM215 | 55 | 2980 | — | 697 | |||
| CDM215-2 | CDM215 | 75 | 2980 | — | 847 | |||
| CDM215-3-A-2B | CDM215 | 75 | 2980 | — | 865 | |||
| CDM215-3-3A | CDM215 | 90 | 2980 | — | 883 | |||
| CDM215-4-2A-2B | CDM215 | 110 | 2980 | — | 1340 | |||
| CDM215-4 | CDM215 | 132 | 2980 | — | 1428 | |||
| CDM215-5-3A-2B | CDM215 | 132 | 2980 | — | 1447 | |||
| CDM215-5-5A | CDM215 | 160 | 2980 | — | 1569 | |||
| CDM215-5 | CDM215 | 160 | 2980 | — | 1569 | |||
| CDM215-6-3A-3B | CDM215 | 160 | 2980 | — | 1589 | |||
| CDM215-6-5A-B | CDM215 | 200 | 2980 | — | 1530 | |||
| CDM215-6 | CDM215 | 200 | 2980 | — | 1530 | |||
| CDM215-7-5A-2B | CDM215 | 200 | 2980 | — | 1548 | |||
| CDM255-1-1 | CDM255 | 30 | 2980 | — | 495 | |||
| CDM255-1 | CDM255 | 37 | 2980 | — | 515 | |||
| CDM255-2-2 | CDM255 | 55 | 2980 | — | 697 | |||
| CDM255-2 | CDM255 | 75 | 2980 | — | 843 | |||
| CDM255-3-2 | CDM255 | 90 | 2980 | — | 882 | |||
| CDM255-3 | CDM255 | 110 | 2980 | — | 1338 | |||
| CDM255-4-2 | CDM255 | 132 | 2980 | — | 1422 | |||
| CDM255-4 | CDM255 | 160 | 2980 | — | 1542 | |||
| CDM255-5-3 | CDM255 | 160 | 2980 | — | 1561 | |||
| CDM255-5 | CDM255 | 200 | 2980 | — | 1502 | |||
| CDM255-6-2 | CDM255 | 200 | 2980 | — | 1522 |
Performance range
Every model of the CDM(F) rated range on one chart: each dot is the rated duty point of one model. Click a line or dot to open that model with its full data.
- CDM1
- CDM3
- CDM5
- CDM20
- CDM95
- CDM125
- CDM155
- CDM185
- CDM215
- CDM255
Logarithmic scales. Published catalogue data for clean water; the correct model for your duty is confirmed by our engineers.
Dimensions & weight
Net weight and the main dimensions of each model, in millimetres, from the catalogue. Open a model for the labelled dimension drawing.
Spare parts for CDM(F) rated
Typical wear and service parts for this type of pump. The exact part, material and part number depend on the model, so send us the model code (or a nameplate photo) and we confirm and quote the right one.
| Part | What it does | |
|---|---|---|
| Mechanical seal | Seals the shaft; the most frequently replaced part | |
| Impeller | Transfers energy to the liquid | |
| Shaft sleeve | Protects the shaft in the seal area | |
| Bearings | Carry the shaft; replace on noise or heat | |
| Wear ring | Keeps the clearance between impeller and casing | |
| O-rings and gaskets | Seal the casing joints | |
| Coupling | Connects motor and pump |
Generic list for this pump type; it is not a part-number catalogue for the series. Our team confirms the correct part for your model before quoting.
Specification & options
Key parameters
- Medium temperature (normal)-15 to +70 C
- Medium temperature (high)-15 to +120 C
Technical data
Liquid temperature
- -15 to +70 C
- -15 to +120 C
Typical applications
- Boosting, pressurising, HVAC and water treatment
Data basis
- CDM(F) model list supplied as CDMF.xlsx
Performance values are taken from the published CNP catalogue data. Our engineers confirm the final selection for your liquid, temperature, supply and site before quoting.
Other other pumps
CDLK rated
Immersion multistage centrifugal pump (rated points)
- Flow 1–20 m³/h
- Head up to 194 m
- 0.75–18.5 kW
CHM rated
Light horizontal multistage centrifugal pump (rated points)
- Flow 1–25 m³/h
- Head up to 61 m
- 0.25–7.5 kW