WLT list
Horizontal cooling tower pump (rated points), WLT / WLTS / WLTSF horizontal cooling tower pump (list models not in the older data)
WLT list: horizontal cooling tower pump (rated points) from the CNP range. 6 models, flow 30 to 400 m³/h, head up to 10.5 m, motors 0.55 to 15 kW. Typical duties: closed cooling tower and condenser water circulation; large flow, low head duties. Open a model for its rated duty, dimensions and datasheet, or send us your duty and we will confirm the selection.
- Flow
- Staff only
- Head
- Staff only
- Power
- 0.55–15 kW
- Mains
- 50 Hz
- Models
- 6
- Liquid temp.
- -15 to +100 C
Models
Filter by duty point, mains frequency or size. Click a model for its performance curve and data.
| Model | Series | Power kW | rpm | Outlet | kg | |||
|---|---|---|---|---|---|---|---|---|
| WLT150-7.5/7.5 | WLT | 7.5 | 1450 | DN150 | 118 | |||
| WLTS65-4/0.55 | WLTS | 0.55 | 2900 | DN65 | 24.5 | |||
| WLTS65-5A/0.75 | WLTS | 0.75 | 2900 | DN65 | 30 | |||
| WLTS150-7.5/7.5 | WLTS | 7.5 | 1450 | DN150 | 133.5 | |||
| WLTS200-8.5/11 | WLTS | 11 | 1480 | DN200 | 274 | |||
| WLTS200-10.5/15 | WLTS | 15 | 1480 | DN200 | 290 |
Performance range
Every model of the WLT list range on one chart: each dot is the rated duty point of one model. Click a line or dot to open that model with its full data.
- WLT
- WLTS
Logarithmic scales. Published catalogue data for clean water; the correct model for your duty is confirmed by our engineers.
Dimensions & weight
Net weight and the main dimensions of each model, in millimetres, from the catalogue. Open a model for the labelled dimension drawing.
| Model | Weight (kg) | Impeller dia | Inlet bore |
|---|---|---|---|
| WLT150-7.5/7.5 | 118 | 212 | 150 |
| WLTS65-4/0.55 | 24.5 | 86 | 65 |
| WLTS65-5A/0.75 | 30 | 88 | 65 |
| WLTS150-7.5/7.5 | 133.5 | 212 | 150 |
| WLTS200-8.5/11 | 274 | 218 | 200 |
| WLTS200-10.5/15 | 290 | 238 | 200 |
Spare parts for WLT list
Typical wear and service parts for this type of pump. The exact part, material and part number depend on the model, so send us the model code (or a nameplate photo) and we confirm and quote the right one.
| Part | What it does | |
|---|---|---|
| Mechanical seal | Seals the shaft; the most frequently replaced part | |
| Impeller | Transfers energy to the liquid | |
| Shaft sleeve | Protects the shaft in the seal area | |
| Bearings | Carry the shaft; replace on noise or heat | |
| Wear ring | Keeps the clearance between impeller and casing | |
| O-rings and gaskets | Seal the casing joints | |
| Coupling | Connects motor and pump |
Generic list for this pump type; it is not a part-number catalogue for the series. Our team confirms the correct part for your model before quoting.
Specification & options
Key parameters
- Medium temperature-15 to +100 C
- Maximum working pressure6 bar
Technical data
Liquid temperature
- -15 to +100 C
Typical applications
- Closed cooling tower and condenser water circulation
- large flow, low head duties
Data basis
- Model list supplied as WLT.xlsx
Performance values are taken from the published CNP catalogue data. Our engineers confirm the final selection for your liquid, temperature, supply and site before quoting.
Other other pumps
CDLK rated
Immersion multistage centrifugal pump (rated points)
- Flow 1–20 m³/h
- Head up to 194 m
- 0.75–18.5 kW